Autoclave
An autoclave is a pressure-vessel sterilizer that uses saturated steam at high temperature to sterilize reusable, heat-stable instruments, the standard on-site clinic method.
Precise definitions of the terms used across hair restoration instruments, procurement and clinic practice — written for professional buyers, not patients.
An autoclave is a pressure-vessel sterilizer that uses saturated steam at high temperature to sterilize reusable, heat-stable instruments, the standard on-site clinic method.
A bevel is the angled surface ground onto a punch or blade edge to form its cutting geometry, where the angle trades sharpness against edge strength.
Biocompatibility is the degree to which a material performs its intended function in contact with tissue without provoking a harmful local or systemic biological response.
A cannula is a slim tube, frequently blunt-tipped, used to move fluid into or out of tissue, specified by gauge, length and tip type and joined to a syringe by a luer fitting.
Coring is the cutting action by which an FUE punch scores a cylindrical column of tissue around a follicular unit so the graft can be freed from the surrounding skin.
A cutting edge is the sharpened apex where a punch or blade parts tissue — the line where two ground surfaces meet, whose keenness governs how cleanly it cuts.
Direct Hair Implantation, an FUE technique that places grafts using an implanter pen in a single incise-and-insert action.
The number of follicular units present per square centimetre of the donor scalp, measured before harvesting.
EO sterilization uses ethylene oxide gas to sterilize heat- and moisture-sensitive devices at low temperature, commonly used for single-use plastics that steam would deform.
The natural cluster of one to four hairs that emerge together as a single anatomical bundle in the scalp.
Follicular Unit Excision, a technique that harvests grafts individually with a small circular punch rather than a strip.
Follicular Unit Transplantation, the strip method in which a band of donor scalp is removed and dissected into grafts.
Gamma sterilization uses ionizing gamma radiation to sterilize devices inside their final sealed packaging at ambient temperature, common for single-use medical disposables.
Whether transplanted follicular units re-establish a blood supply and go on to produce hair in the recipient site.
Holding extracted follicular units in a chilled solution to slow their metabolism during the out-of-body interval.
An implanter pen is the pen-shaped device used in DHI to load a graft into a hollow needle and place it directly into the scalp in a single motion.
Inner vs outer diameter is the pair of measurements that defines a punch — the lumen the graft passes through versus the wound the donor heals, separated by the wall thickness.
Instructions for use (IFU) are the manufacturer's supplied directions covering a device's intended use, handling, reprocessing limits and storage, provided with the product.
A recipient-site incision oriented parallel to the direction of natural hair growth to guide graft angle.
A lot number is a code identifying the manufacturing batch a device belongs to, printed on its packaging to make each unit traceable back to its production run.
A luer lock is a threaded connector that mechanically secures a syringe, cannula or tube to its counterpart on a standardized taper, resisting accidental disconnection under pressure.
A micromotor is the compact electric drive unit that spins or oscillates an FUE punch, supplying the speed and torque that carry the cutting edge through tissue.
Punch gauge is a legacy needle-sizing scale sometimes applied to FUE punches, where a higher number means a smaller bore — which is why millimetres are the professional unit.
RPM (revolutions per minute) is the rotational speed of an FUE micromotor and punch — how many full turns the cutting edge makes each minute.
A sapphire blade is a recipient-incision blade cut from synthetic sapphire — a hard crystalline ceramic that holds a fine edge — used to make recipient sites.
Shelf life is the period a sealed device stays fit for use under stated storage conditions, indicated by an expiry date and conditional on the package remaining intact.
A sterile barrier system is the minimum sealed package that maintains the sterility of a device until the point of use and allows aseptic presentation of its contents.
Torque is the rotational force a micromotor delivers to a punch — the turning force that keeps the cutting edge advancing through tissue without stalling.
The share of harvested follicular units cut or damaged during extraction, expressed as a proportion of units attempted.
The infiltration of dilute fluid into the scalp to firm the tissue and disperse anesthetic before harvesting.